CMM Calibration and Repair in Memphis, TN
Memphis CMM Calibration and Repair
Request a quotation for on-site or ship-in CMM service.

Request a quotation
Performance verification, not a slogan
A CMM performance verification checks the machine against ISO 10360-2 or ASME B89.4.1, not against a feeling that it still measures well. As-found data is captured before any adjustment, and an as-left result is issued once geometry and compensation are updated.
Shops searching for CMM calibration near you are usually a week from an audit. Work is performed by laboratories accredited to ISO/IEC 17025:2017, with results traceable to the SI through NIST, on-site or ship-in.


What a visit actually covers
Scales, reader heads, air bearings and squareness are inspected before any length test runs. The ISO 10360-2 length measurement error test follows, with probing error checked on a separate calibrated sphere per ISO 10360-5.
Portable arms, rotary tables and laser trackers each have a dedicated acceptance standard, distinct from the ISO 10360-2 certificate issued to a bridge machine.
Services
Calibration and repair, programming, and the gage crib that travels with the CMM can be scheduled as one request instead of three separate vendors.
CMM Calibration and Repair
Performance verification against ISO 10360 or ASME B89, with as-found data, geometric adjustment and certificate issue.
Get a quotation →CMM Programming
Offline and online part programs built from print or model, with GD&T interpretation and PPAP-ready reporting.
Get a quotation →Gage Calibration
Calipers, micrometers, gage blocks, pin and thread gages, and surface plates, on one recall schedule with the CMM.
Get a quotation →
Service areas across West Tennessee and the Mid-South
Memphis sits at the center of a supplier base that runs down the I-55 corridor into north Mississippi and east into west Tennessee, reaching Horn Lake, West Memphis, Marion and Forrest City.
Scheduling also covers smaller stops along those same routes — Marianna, Turrell, Walls, Earle, Clarkedale and Hughes — where a shop runs one CMM and cannot afford it stopped any longer than the visit takes.
Why Memphis CMM Calibration and Repair
- 01
As-found before adjustment
Data is recorded before geometry or compensation is touched, preserving the impact-assessment trail.
- 02
Standard matched to the frame
Bridge, arm, rotary table and tracker each run against the standard that applies to it.
- 03
On-site or ship-in
Scheduling works around inspection-department downtime, not the other way around.
- 04
Traceable certificates
Results trace to the SI through NIST, with uncertainty and method stated on the certificate.
Common questions
Is there CMM calibration near me in Memphis and the surrounding area?
On-site service covers Memphis and the Mid-South, reaching down the I-55 corridor into north Mississippi and east into west Tennessee. Outside that radius, travel is quoted separately or ship-in service is arranged instead.
What is the difference between calibration and verification?
Calibration establishes the relationship between the machine's indications and reference values with a stated uncertainty. Most CMM work sold under that name is a performance verification against ISO 10360 or ASME B89, checking the machine against a stated specification.
What happens if the machine fails the as-found test?
As-found data is recorded before adjustment, and failure is reported with the measured values, not just a pass/fail flag. That data is what supports a reverse-traceability review of parts accepted since the last passing calibration.

Discuss CMM Calibration and Repair Requirements
Send the machine details and get a scheduling window back.