Quality System
Quality System & Standards
The standards, traceability and management arrangements that govern the work described on this site.
Overview
Calibration and verification work for Memphis CMM Calibration and Repair is performed by laboratories accredited to ISO/IEC 17025:2017, and certificates are issued under the performing laboratory's accreditation scope. Scope matching happens before a quotation is written, not after a machine is already on the truck.

Standards Referenced
Work described on this site is performed under ISO/IEC 17025:2017.
Any accreditation named on this site belongs to the laboratory performing the measurement. It covers the quantities and ranges written into that laboratory's published scope and nothing beyond them. Work falling outside that scope is still carried out, but it is reported as non-accredited and marked that way on the certificate, so the status of every line is readable from the document itself.
The documentation a quotation arrives with is explained on the accreditation documentation page.

Metrological Traceability
Each request is checked against the performing laboratory's published scope of accreditation for the instrument, range and uncertainty involved before the job is booked. Accredited and non-accredited items on a mixed order, such as a CMM alongside hand gages, are identified separately on the quote and again on the certificate, so an auditor can see which results fall inside scope. Measurements are traceable to the SI through NIST; the chain of comparisons and the stated uncertainty are carried on the certificate itself, alongside the method and reference standards used, including laser tracker verification under ISO 10360-10 where that frame type applies. Where a statement of conformity is given, the decision rule applied is stated on the certificate, consistent with ISO 14253-1 and the guard-banding practice described in ANSI/NCSL Z540.3.
Traceability is recorded per measurement, not per site: the certificate names the reference standard used, its own calibration status, and the chain by which that standard is linked to the SI unit. Where a reference is found out of tolerance, the work performed against it since its previous calibration is reviewed and affected customers are notified.
Equipment and Maintenance
Equipment handled includes bridge, gantry and cantilever coordinate measuring machines, portable articulated arms, granite surface plates, gauge blocks, and ring and plug gauges. Out-of-tolerance findings are reported with as-found data recorded before any adjustment, supporting a reverse-traceability impact assessment back to the last passing calibration. Records, asset identifiers and due-date recall notices are retained so a certificate can be retrieved on short notice during a registrar or customer audit.
Each reference has its own identity, controlled storage and use, and a recalibration interval set in advance and pulled in when drift data says it should be. Equipment that is damaged, overloaded or suspect is pulled from service and marked, and comes back only after a check and a written release.
Management System
The work sits inside a documented management system:
- 01
Controlled documents
Procedures carry issue and revision status.
- 02
Retained records
Retained for a defined period and retrievable against a certificate number.
- 03
Audit and review
Internal audit and management review run on a schedule.
- 04
Corrective action
Nonconforming work and improvement actions are tracked to closure, and their effectiveness is checked afterwards.
Impartiality and Complaints
Risks to impartiality are identified and kept under control, and results stand on the evidence regardless of who benefits. Complaints and appeals enter the management system formally — the process, including the response commitment, is set out on the complaints policy page. How results should and should not be read is covered on the disclaimer page.

Compiling records for a supplier-qualification file?
Scope, method statements and traceability detail are supplied with the quotation.