Verification, not a label

Calibration establishes a measured relationship with a stated uncertainty. What most machines need, and what gets booked under that name, is performance verification against ISO 10360-2 or ASME B89.4.1 — confirming the machine still meets its stated specification.

Each frame type carries its own test standard: a bridge or gantry machine is verified under ISO 10360-2, a portable arm under ISO 10360-12 or ASME B89.4.22, and a rotary table fourth axis under ISO 10360-3, where applicable to the configuration on site.

The sequence of a visit

Each visit runs in the same order regardless of frame type, starting with the parts of the machine that drift fastest.

  • 01

    Scales and reader heads

    X, Y and Z scales are inspected and cleaned; reader head output is checked before geometry testing.

  • 02

    Air bearings and airlines

    Bearing condition and supply pressure are checked; contamination here shows up as noise in the length test.

  • 03

    Geometry

    Straightness, linearity and squareness are measured in the XY, ZX and ZY planes.

  • 04

    Length and probing error

    ISO 10360-2 length measurement error at 105 measurements, and probing form error, designated PFTU under ISO 10360-5, measured at 25 points on a dedicated test sphere.

As-found to as-left

  • 01

    As-found test

    Results are captured against the stated MPE before any adjustment is made.

  • 02

    Adjustment

    Geometric errors are corrected and, where the controller allows it, the volumetric compensation map is updated.

  • 03

    As-left verification

    The length and probing tests are repeated to confirm the machine meets specification.

  • 04

    Certificate issue

    Results, uncertainty, method and traceability are issued under the performing laboratory's scope.

Why Memphis CMM Calibration and Repair

  • 01

    As-found recorded first

    Adjustment never happens before the as-found data is on record.

  • 02

    Repair alongside calibration

    Probe heads, scales, air bearings and drives are serviced without a second vendor visit.

  • 03

    Frame-appropriate standard

    Arms, trackers and rotary tables are tested where applicable to that configuration, not treated as bridge-machine extensions.

Coverage across West Tennessee and the Mid-South

On-site scheduling and ship-in service are available across the Mid-South; travel terms and radius are confirmed at quote.

Discuss CMM Calibration and Repair Requirements

Scope a calibration or repair visit now.

A written quotation is sent back by email.
Quote + DocumentationEmail us