Skip to content
Quote + Documentation

About Us

About Us

How the work is organized, and what has stayed constant while it grew.

Disciplines 3Service areas 6Coverage West Tennessee and the Mid-South

Background

Memphis CMM Calibration and Repair arranges performance verification, repair and programming for coordinate measuring machines used by manufacturers across West Tennessee and the Mid-South. Work is placed with laboratories accredited to ISO/IEC 17025:2017, matched against each laboratory's published scope before a job is scheduled. Measurement and certificate issue are completed by that performing laboratory, with scope checked against the instrument before anything is booked in.

A Look Back

The buyer base runs from Tier 2 and Tier 3 suppliers to independent job shops, most of them holding a CMM that a registrar or customer audit requires kept current. Power equipment manufacturing anchors a large share of that base in this region — transformer, switchgear and tap-changer work carries coil and winding concentricity, core stack lamination flatness, and bushing and terminal location tolerances that a length measurement error test under ISO 10360-2 is built to confirm. Scheduling covers on-site visits across the Mid-South and ship-in service for smaller instruments and gages, with routes planned around inspection-department downtime so a shop's inspection work loses as little time as possible.

Equipment handled spans bridge, gantry and cantilever CMMs, portable articulated arms, granite surface plates, gauge blocks, and ring and plug gauges. Each request is checked against a laboratory's accredited scope before a quotation is issued, and accredited and non-accredited items are identified separately on both the quote and the certificate. Certificates carry NIST-traceable calibration results, with the method, reference standards and reported uncertainty stated alongside the measurement.

The Reference Points for the Work

These are the operating commitments the work is measured against.

  • 01

    As-found first

    Data is recorded before adjustment on every visit, without exception.

  • 02

    Scope before quote

    Every request is checked against a laboratory's accredited scope before pricing is returned.

  • 03

    Standard matched to frame

    Bridge, arm, rotary table and tracker are each tested to the standard that applies.

  • 04

    Documented traceability

    Results trace to the SI through NIST, stated with method and uncertainty on the certificate.

More to Explore

The standards, traceability arrangements and management system behind the work are set out on the quality system page. The competence framework behind the people doing it is set out on the our team page.

Reviewing a new supplier?

Turnaround, scope and documentation detail are provided with the quotation.